Selection of heating elements

The right selection of heating elements

By selection of heating element very important role play application and conditions of work. Size, power and surface load of heating element depend on different factors. To satisfy your needs fully we need to find out your exact requirements with respect to:

  • application
  • heated medium
  • required temperature
  • permissible size
  • rated voltage
  • rated power
  • electric terminals
  • control of temperature

Required temperature

Temperatura vs. obciążenie pow.

Material of sheath
Permissible maximum temperature
A - steel alloy 20%Cr 30%Ni (e.g. Incoloy 800) max. 800 °C
B - steel alloy 18%Cr, 9%Ni (e.g. AISI-321) max. 650 °C
C - chromium steel max. 600 °C
D - carbon steel max. 350 °C
E - aluminium max. 300 °C
F - copper, brass max. 250 °C

Surface load

Permissible surface loads of heating elements in W/cm2 vary with conditions of work

Application
Material of the tube
copper
steel
steel alloy (AISI 304) steel alloy (Incoloy 800)
still water
10 - 10 -
forced water
14 - 14 -
forced water
(immediate water heaters)
25 - 25 -
water vapour
6 - 6 -
thin oil
- 3,5 3,5 -
thick oil
- 1,2 1,2 -
special heating oil (heaters)
- 12 12 -
still air
- 1,7 5 6
forced air
v=2 m/s
- 2 5,5 6,5
forced air
v=10 m/s
- 5 10 10

Dobór_obciążenie_1

Dobór_obciążenie_2

Dobór_obciążenie_3

Dobór_obciążenie_4

Trwałość

Przeciętny czas pracy elementu grzejnego zależy głównie od temperatury pracy wewnętrznego drutu oporowego, która to z kolei jest funkcją temperatury powierzchniowej płaszcza oraz obciążenia powierzchniowego części grzejnej elementu.

Dobór_obciążenie_7

Photovoltaics

SELFA PV - moduy fotowoltaiczne

Tenders

inwest

Recommended

Band heater (micanite inculation) GOGO-06138 »

Get our catalogue

SELFA GE - katalog PDF polski (12 MB)   SELFA GE - english catalogue PDF (20 MB)